Honeywell V8600C1053 Gas combination valve
Application
Gas boiler and hot air device with "allgas" setting option.
Threaded connection
R 1/2" DIN 2999, straight passage with dirt filter
Ignition gas connection:
M 11 x 1 for 4 and 6 mm Ø ignition gas connection
Max. power:
approx. 22 kW or 20000 kcal/h (dv = 0.45) town gas
approx. 36 kW or 32000 kcal/h (dv = 0.64)
at 2.5 mbar pressure loss
Input pressure
max. 50 mbar
Information
V 4600 C 1086 U replaces V 4600 C 1029, V 4600 C 1086, V 4600 C 1052,
V 4600 C 1128, V 4600 C 1102
V 8600 C 1053 U replaces V 8600 C 1020, V 8600 C 1145
Delivery without cover.