null
Skip to main content

Siemens 5WG1524-4DB23, RL 524D23

£97.77
(No reviews yet) Write a Review
SKU:
5WG1524-4DB23
Availability:
Usually ships within 4-5 working days.
Shipping:
Calculated at Checkout
Adding to cart… The item has been added

Siemens 5WG1524-4DB23, RL 524D23

  • For control of drives with a DC motor for DC 24 V

  • Two relays per output for polarity switching of the output voltage

  • Rated contact operating voltage DC 24 V

  • Rated contact current: 6 A

  • Electronics for detection of the actuation of an electromechanical and electronic limit switches

  • Automatic travel time determination via current detection

  • Maintenance-free terminals for connection and through-wiring of untreated single-core, stranded or multi-core conductors, 0.5 ... 2.5 mm²

  • Two terminals per actuator channel for motor connection (up, down)

  • Two terminals on the device to connect the DC 24 V (+/-) to supply the load circuits

  • Bus-powered electronics

  • Housing: plastic

  • As built-in device for mounting in a separately to be ordered Control Module Box AP 118

  • Type of protection: IP 20

Additional functionalities GAMMA

  • Selectable operation mode blinds, shutter/awning, ventilation flap
  • Per actuator channel motion commands for moving and stopping the solar protection or for adjustment of blind slats
  • Per actuator channel direct movement to a position of the sunblind and the blind slats
  • Per actuator channel central movement of the solar protection in manual mode and automatic mode and delay time for Up / Down
  • Distinction between automatic and manual mode (position of the sunblind and blind slats) and adjustable behaviour in sunshine
  • Programming and recalling preset positions 1-4 and 8-bit scene control
  • Adjustable behaviour in case of override (wind, rain, frost, lock, forced position, forced control, range limitation)
  • Adjustable reverse pause time and delay times of the drives
  • Per actuator channel configurable state on bus voltage failure and start value on bus voltage recovery
  • Adjustable transmission of status objects (automatic operation, curtain and slat position, travel, calibration travel time to end positions, overriding) on request, cyclically and/or upon change
  • Adjustable transmission time of the status objects after bus voltage recovery and transmission delay between the status objects
  • Surveillance of device function

Additional info

The automation module box AP 118 must be ordered separately.See chapter Modular installation system, Room automation box - Housing.

HS CODE: 85371091

COO: Romania