Siemens 5WG1528-1DB01, N 528D01

  • Two outputs for switching and dimming resistive, inductive or capacitive loads

  • Automatic adjustment to leading edge or trailing edge control, depending on the type of load

  • Rated operational voltage AC 230 V

  • Rated frequency 50 / 60 Hz

  • Rated power at +35°C ambient temperature: 300 VA per output or 500 VA for single output usage, without any minimal load per output

  • Electronic protection of each output against overload, short circuit and temperature rise

  • Screw terminals for connection and through-wiring of untreated single-core, stranded or multi-core conductors, 0.5 ... 2.5 mm²

  • Bicolor LED for indicating the switch status (red = on, green = off) or an error (orange, blinking) per output

  • Bus-powered electronics

  • Integrated bus coupling unit, bus connection via bus terminal block

  • Device for DIN-rail mounting on a TH35 mounting rail according to DIN EN 60715

Additional functionalities GAMMA

  • Per output with selectable mode (normal mode, one- or two-level timer mode, blinking)

  • Adjustable ON- and OFF-delay

  • Separately adjustable dimming time from 0% to 100% for switching on/off and dimming brighte/darker

  • The ability to switch an output on or off by dimming brighter/darker

  • Adjustable dimming value when switching on

  • Immediate activation (jumping) or dimming to a new dimming value

  • Selectable additional status object switching and/or status object dimming value for each output

  • Additional object for each output for blocking/releasing the output

  • Sending of status objects on request and/or automatically after a change

  • Adjustable blocking time for sending status objects after restart and bus voltage recovery

  • Adjustable dimming value for each output in the event of bus voltage failure and recovery

  • Additional night mode object for time-limited switching on the output (and hence illumination) at night

  • Adjustable ON period at night or with timer mode

  • Selectable warning of imminent switching off the illumination by dimming to 50% of the previous dimming value during night mode or timer mode

  • Integrated 8-bit scene control and integration of each output in up to 8 scenes

  • Separately adjustable dimming time for scene control

  • Selectable counting of operating hours and with threshold monitoring of the operating hours

  • Selectable counting of load cycles and with threshold monitoring of the load cycles

  • Optional disabling of the ripple control compensation in an electrical grid with frequency fl uctuations

  • Building site function for switching the building site lighting on and off even if the bus devices have not yet been commissioned with ETS