Siemens 5WG1528-1DB01, N 528D01
-
Two outputs for switching and dimming resistive, inductive or capacitive loads
-
Automatic adjustment to leading edge or trailing edge control, depending on the type of load
-
Rated operational voltage AC 230 V
-
Rated frequency 50 / 60 Hz
-
Rated power at +35°C ambient temperature: 300 VA per output or 500 VA for single output usage, without any minimal load per output
-
Electronic protection of each output against overload, short circuit and temperature rise
-
Screw terminals for connection and through-wiring of untreated single-core, stranded or multi-core conductors, 0.5 ... 2.5 mm²
-
Bicolor LED for indicating the switch status (red = on, green = off) or an error (orange, blinking) per output
-
Bus-powered electronics
-
Integrated bus coupling unit, bus connection via bus terminal block
-
Device for DIN-rail mounting on a TH35 mounting rail according to DIN EN 60715
Additional functionalities GAMMA
-
Per output with selectable mode (normal mode, one- or two-level timer mode, blinking)
-
Adjustable ON- and OFF-delay
-
Separately adjustable dimming time from 0% to 100% for switching on/off and dimming brighte/darker
-
The ability to switch an output on or off by dimming brighter/darker
-
Adjustable dimming value when switching on
-
Immediate activation (jumping) or dimming to a new dimming value
-
Selectable additional status object switching and/or status object dimming value for each output
-
Additional object for each output for blocking/releasing the output
-
Sending of status objects on request and/or automatically after a change
-
Adjustable blocking time for sending status objects after restart and bus voltage recovery
-
Adjustable dimming value for each output in the event of bus voltage failure and recovery
-
Additional night mode object for time-limited switching on the output (and hence illumination) at night
-
Adjustable ON period at night or with timer mode
-
Selectable warning of imminent switching off the illumination by dimming to 50% of the previous dimming value during night mode or timer mode
-
Integrated 8-bit scene control and integration of each output in up to 8 scenes
-
Separately adjustable dimming time for scene control
-
Selectable counting of operating hours and with threshold monitoring of the operating hours
-
Selectable counting of load cycles and with threshold monitoring of the load cycles
-
Optional disabling of the ripple control compensation in an electrical grid with frequency fl uctuations
-
Building site function for switching the building site lighting on and off even if the bus devices have not yet been commissioned with ETS
HS CODE: 85371091